12-18
With the rapid development of social economy, people\\\'s living standards have been improved day by day, and the scale of greenhouse farming has been increasing year by year. However, in the implementation of the national green development plan, extensive aquaculture has been gradually limited and eliminated, and green and integrated development is the general trend. At the same time, with the increasing scale of the industry, many disadvantages of the traditional breeding structure have gradually emerged.
01-12
With the shortlist of energy-saving subsidy project, air energy heat pump units have gradually entered thousands of households. Being able to use air energy heat pump units has also become a basic living ability of people. In the process of use, people usually encounter many problems. The following is a detailed explanation of the common fault analysis and diagnosis of the air energy heat pump unit. 14.jpg 1、 Fan does not rotate Fault analysis: it may be that the secondary high voltage is open circuit, or the power supply is not connected, or the capacitor is broken, or the motor is burned out. Diagnosis: check the sub high voltage switch for short circuit test. If it is broken, replace it immediately. Measure the line voltage, check the capacity of the capacitor, and replace the capacitor. 2、 The unit does not rotate and there is no display Fault analysis: it may be the power supply fault or the fuse is burnt out, the thermal overload protector is burnt out and the power line is loose. Diagnosis: First cut off the power, then check the power switch, update the power cord, and check the unit. 3、 Frost on compressor surface Fault analysis: It may be that the temperature sensor falls off due to expansion, or the expansion valve fails, or the chip is stuck, the temperature setting is wrong, or the refrigerant is not prepared enough. Diagnosis: readjust the device inside, replace the thermal expansion valve, readjust the temperature sensor, and pay attention to cleaning and inspection 4、 The compressor is noisy Fault analysis: the fixed part of the internal pipeline loosens and produces vibration, the thermal expansion is too large, the oil pressure is too low, or the muffler is damaged. Diagnosis: adjust the opening of the thermal expansion valve, check and fasten the compressor pipeline, and replace the lubricating oil and muffler.
05-17
The general heating method is to directly use energy to heat water. The energy efficiency of electric water heater is about 95%, and that of natural gas is about 75%. The heat pump unit uses electric energy to drive the compressor, not directly used to heat water. The heat energy actually comes from the environment.
Explore more exciting videos
Find reliable purchasing channels
GEME Air is happy to serve you
24-hour specialist to solve problems for you
Looking forward to becoming a partner with you
Guangdong GEME Refrigeration Equipment Co., Ltd
Address: No. 31 Eastern Industrial Park,Lishui Town,NanHai,Foshan,Guangdong,China. P.C:528244
24H service telephone:
Guangdong GEME Refrigeration Equipment Co., Ltd. Yue ICP Bei No. 19056255